400KW Yuchai Generator Set

400KW Yuchai Generator Set

Model: KNY400GF
Power: 400KW/500KVA
Engine Model: YC6K660-D30
Engine Structure: 6-cylinder in-line, four-stroke, exhaust turbocharging, water-air intercooled
400KW Yuchai Generator Set, 500KW Yuchai Generator Set
The 400KW Yuchai diesel generator set is an electronic fuel injection unit meeting China National III emission standards. With intelligent control systems, and excellent load capacity, it offers stable power for critical scenarios such as construction sites and data centers, featuring easy maintenance and a long service life.
Send Inquiry
Description
Technical Parameters

Yuchai's 400kW diesel generator sets come standard with proven remote diagnosis tools and electronic intelligent fuel-saving switches. For non-road operations, it adds five targeted smart controls to boost reliability and efficiency:

 

Starter Relay Control: Prevents misstart and extends starter lifespan

 

Integrated Idle Speed Boost Control: Balances parking/driving idle modes for optimal fuel efficiency and quick response

 

Manual Throttle Control: Maintains steady speed via throttle adjustment for specific load needs

 

Fuel Water Ingress Alarm: Triggers alerts when water content exceeds safe levels, protecting the engine

 

Fault Flash Code Output: Displays real-time faults via light signals-no diagnostic tools required

 

This suite of smart features streamlines operation, cuts maintenance costs, and ensures stable performance in harsh off-grid environments.

 

image003

 

Multiple Configurations, Wide Applications

 

The 400kW Yuchai diesel generator set delivers robust power, exceptional durability, and easy maintenance.

Featuring precision nozzle metering technology, it achieves lean combustion with high thermal efficiency, ensuring low fuel consumption.

Available configurations: Standard type, silent type, trailer-mounted type, mobile power stations and gas generators.

The 400kW Yuchai diesel generator set adopts internationally synchronized advanced technologies, specifically designed to serve as backup power for quarries, farms, hospitals, hotels, factories, and schools.

 

image005

 

Below is the standard configuration list for the 400kw Yuchai diesel generator set. Please review it carefully before deciding whether additional configurations are required.

 

image007

image009

 

400KW Yuchai Generator Set Parameter Table

 

Generator Model

Diesel Generator

Diesel Engine

Alternator

Size Lx WxH (mm)

Weight (KG)

Prime Power (KW/KVA)

Standby Power (KW/KVA)

Model

Power (KW)

Model

Power (KWIKVA)

KNY20GF

20/25

22/27.5

YC4V35-D20

23/25

KN-20

20/25

1800x750x1200

920

KNY30GF

30/37.5

33/41.25

YC4V45-D20

30/33

KN-30

30/37.5

1800x750x1200

950

KNY35GF

35/43.75

40/50

YC4V55Z-D20

38/42

KN-35

35/43.75

1800x700x1200

980

KNY40GF

40/50

44/55

YC4D60-D25

40/44

KN-40

40/50

1800x700x1200

1000

KNY50GF

50/62.5

55/68.75

YC4D90Z-D21

60/66

KN-50

50/62.5

2250x800x1300

1250

KNY60GF

60/75

66/82.5

YC4A100Z-D25

70/77

KN-60

60/75

2300x800x1300

1500

KNY75GF

80/100

88/110

YC4A140L-D25

100/110

KN-80

80/100

2300x830x1300

1600

KNY100GF

100/125

110/137.5

YC4A180L-D20

120/132

KN-100

100/125

2400x970x1500

2100

KNY120GF

120/150

132/165

YC6B205L-D20

138/152

KN-120

120/150

3100x1050x1750

2750

KNY150GF

150/187.5

165/206.25

YC6A245L-D21

165/181

KN-150

150/187.5

3200x1150x1750

3000

KNY200GF

200/250

220/275

YC6MK350L-D20Y

235/258

KN-200

200/250

3200x1200x1750

3100

KNY250GF

250/312.5

275/343.75

C6MK420L-D20

281/309

KN-250

250/312.5

3400x1500x1970

3900

KNY300GF

300/375

330/412.5

YC6MJ500L-D21

334/367

KN-300

300/375

3500x1500x1970

4000

KNY350GF

350/437.5

385/481.25

YC6K600-D30

401/441

KN-350

350/437.5

3500x1500x1970

4500

KNY400GF

400/500

440/550

YC6K660-D30

441/490

KN-400

400/500

4500x1800x2500

7500

KNY500GF

500/625

550/687.5

YC6TD840-D30

561/616

KN-500

500/625

5000x2000x2500

9800

KNY600GF

600/750

660/825

YC6TD1000-D30

668/735

KN-600

600.75

5300x2080x2500

10000

KNY800GF

800/1000

880/1100

YC6TH1320-D31

880/968

KN-800

800/1000

5600x2280x2600

12000

KNY1000GF

1000/1250

1100/1375

YC6C1660-D31

1110/1221

KN-1000

1000/1250

5600x2280x2600

12000

KNY1200GF

1200/1500

1320/1650

YC12VC2070-D31

1380/1520

KN-1300

1200/1500

5600x2280x2600

13000

KNY1500GF

1500/1875

1650/2062.5

YC12VC2700-D31

1805/1985

KN-1600

1500/1875

5600x2280x2600

14000

KNY1800GF

1800/2250

1980/2475

YC16VC330C-D31

2205/2426

KN-1800

1800/2250

5600x2280x2600

14000

KNY2000GF

2000/2500

2200/2750

YC16VC4C0C-D31

2673/2940

KN-2000

2000/2500

5600x2280x2600

14000

 

Please note:

1. The above technical parameters are 50hz, rated voltage 400/230V, power factor 0.8, 3-phase 4-wire, 60Hz generators can be customized according to the special needs of customers.

2. Alternators can be selected according to the needs of customers are Keneng, Stanford, Leroy- Somer, Marathon and other famous brands.

3. The specifications may change without the notice.

 

Why Choose Us?

 

We firmly believe: With professional equipment and sincere service, we will achieve more pleasant and lasting cooperation.

 

image011

image013

 

Instructions for Diesel Generator Set Operation

 

1. Use 0#~-30# light diesel oil; specify 15W-40 CD grade engine oil (or follow diesel engine manual requirements).
2. Starting temperature: above +5℃; when equipped with water and oil temperature heating device, starting temperature: -15℃. For operation below 0℃, use antifreeze and other low-temperature starting measures.
3. Noise level: ≤85~95dB(A), in compliance with international standards.
4. In addition to 8KW-1600KW land-based generator sets, we also provide marine generator sets of the same power range and various generator sets with 60Hz 1800rpm.
5. Our generator sets comply with GB/T2820 and ISO8528 standards for "Reciprocating Internal Combustion Engine-Driven Generator Sets".
6. Voltage regulation: automatic or manual.
7. Note for users in cold regions: Adjust engine oil, diesel oil, and coolant properly according to temperature changes to ensure normal unit operation.
8. With continuous product updates, if there are changes or modifications to the parameters in the brochure, they shall be subject to the accompanying documents. Our company reserves the right of final interpretation, without prior notice.

 

image015

 

FAQ

 

Q: What is the approximate average fuel consumption rate of the 400kw Yuchai generator set?

A: The average fuel consumption rate is approximately 200-220g/kw·h, which is specifically affected by actual load rate and operating conditions. Fuel consumption is more economical when the load is stable.

Q: How adaptable is the unit to different types of loads (e.g., inductive loads, impact loads)?

A: The unit is designed with good load adaptability, capable of stably handling inductive loads such as motors and water pumps, as well as short-term impact loads. It is recommended to control the load rate within 80% to ensure long-term stable operation.

 

Hot Tags: 400kw yuchai generator set, China 400kw yuchai generator set manufacturers, suppliers, factory, generator set diesel engine 3kw 60hz, generator set 30kva price, dg 62 5 kva, dg 7 5 kva, industrial dg set, 1800KW Yuchai Generator Set